Power Supply: Dual-redundant 600W AC or DC hot-swap power supply (2nd power supply optional)
6 Drive Bays
Slim DVD-ROM
Temperature, operating: +5° C to +40° C (41° F to 104° F
Temperature, short-term operating (<96 hrs): -5° C to 50° C
Temperature, non-operating: -40° C to 70° C (-40° F to 158° F)
Humidity, operating: 5% to 85%
Humidity, short-term operating: 5% to 90%
Humidity, non-operating 93%, non-condensing at temperatures of: 23° C (73° F) to 40° C (104° F)
Altitude 0 to 1,800m (0 to 5,905 ft) @ 40° C 0 to 4,000m (0 to 13,123 ft) @ 30° C
Vibration, operating: Swept sine survey at an acceleration amplitude of 0.1 G from 5 to 100 Hz and back to 5 Hz at a rate of 0.1 octave/minute; 90 minutes per axis on all three axes as per Bellcore GR-63-CORE standards
Vibration, non-operating: Swept sine survey at an acceleration amplitude of 0.5G from 5 to 50 Hz at a rate of 0.1 octaves/minute, and an acceleration amplitude of 3.0 G from 50 to 500 Hz at a rate of 0.25 octaves/minute, on all three axes as per Bellcore GR-63-CORE standard. 2.2 Grms, 10 minutes per axis on all three axes
Shock, operating: Half-sine 2 G, 11ms pulse, 100 pulses in each
direction, on each of the three axes
Safety: UL 60950-1, 1st Edition/CSA 22.2 60950-1, Low Voltage Directive 2006/95/EC, GS to EN60950-1, 1st Edition CB Certificate and Report to IEC60950-1, 1st Edition and all international deviations
Electromagnetic Compatibility USA: FCC 47 CFR Parts 2 and 15, Verified Class A Limit